documentation:software_interface [2020/11/13 11:10] – add link to Redfish API admindocumentation:software_interface [2020/12/16 11:16] vor
Line 1: Line 1:
 ====== Software interface ====== ====== Software interface ======
  
-There are several software interfaces available to monitor the status of the RECS<sup>(r)</sup>%%|%%Box system. These are the Management Web****GUIa REST API providing XML based monitoring and management functionality and a native NRPE based Nagios interface.+There are several software interfaces available to monitor the status of the RECS<sup>(r)</sup>%%|%%Box system. These are the Management Web****GUI and a REST API providing XML based monitoring and management functionality. The Nagios NRPE interface was removed in RECS<sup>(r)</sup>%%|%%Box 4 products.
  
 ===== Management WebGUI ===== ===== Management WebGUI =====
Line 283: Line 283:
 Information about the success or failure of management requests are returned via HTTP status codes. Please have a look at [[http://www.w3.org/Protocols/rfc2616/rfc2616-sec10.html|RFC2616]] for an overview about the defined HTTP status codes. Information about the success or failure of management requests are returned via HTTP status codes. Please have a look at [[http://www.w3.org/Protocols/rfc2616/rfc2616-sec10.html|RFC2616]] for an overview about the defined HTTP status codes.
  
-===== Nagios API ===== 
- 
-The software integration work to monitor the RECS<sup>(r)</sup>%%|%%Box System is quite simple as the the TOR-Master provides monitoring information in the Nagios native NRPE format. So only the NRPE plugin has to be installed and configured as follows. Here, a sample output can be found: 
- 
-<code bash>$ /usr/lib/nagios/plugins/check_nrpe -H 10.11.12.244 \ 
-            -c check_temp -a 10.11.12.244 10 2 70:104 105: 
- 
-OK - Temperature: 29 C|temp=29,000000;70:104;105;70,000000;105,000000 
-</code> 
- 
-The options are used as following: \\ 
- 
-^ Option ^ Description ^ 
-| ''-H'' | Host to ask for data, this is always the IP of the TOR-Master (example: 10.11.12.244) | 
-| ''-c'' | Plugin to run. Can be ''check_temp'' or ''check_power'' | 
-| ''-a'' | Arguments to pass to the plugin, see more details in tables below | 
- 
-Arguments for ''check_temp'' plugin: \\ 
- 
-^ Argument example ^ Description ^ 
-| ''10.11.12.244'' | Get sensor values from device with this IP (RCU/RPU) | 
-| ''10'' | Get sensor values from this baseboard (''1'' - ''18'') | 
-| ''2'' | Get values from this sensor (''max'', ''inlet'', ''outlet'', ''0'', ''1'', ''2'', ''3'', ''4'') | 
-| ''70:104'' | Range of warning threshold | 
-| ''105'' | Range critical threshold (ending with '':'' means open end) | 
- 
-Arguments for the ''check_power'' plugin: \\ 
- 
-^ Argument example ^ Description ^ 
-| ''10.11.12.244'' | Get sensor values from device with this IP (RCU/RPU) | 
-| ''10'' | Get sensor values from this baseboard (''1'' - ''18'') |     
-| ''2'' | Get sensor values from this node (''1'', ''2'', ''3'', ''4'') | 
-| ''80:109'' | Range of warning threshold [Watt] | 
-| ''110:'' | Range of critical threshold [Watt] (ending with '':'' means open end|