documentation:software_interface [2016/12/14 15:26] – [Components] vordocumentation:software_interface [2017/05/23 14:18] – [Nagios API] vor
Line 99: Line 99:
 Example of a backplaneList: Example of a backplaneList:
  
-<code><backplaneList>+<code xml><backplaneList>
 <backplane position="1" id="RCU_84055620466592_BP_1" infrastructurePower="0.0"> <backplane position="1" id="RCU_84055620466592_BP_1" infrastructurePower="0.0">
 <temperatures>24.0</temperatures> <temperatures>24.0</temperatures>
Line 146: Line 146:
 Example XML: Example XML:
  
-<code><backplane position="1" id="RCU_84055620466592_BP_1" infrastructurePower="0.0">+<code xml><backplane position="1" id="RCU_84055620466592_BP_1" infrastructurePower="0.0">
 <temperatures>24.0</temperatures> <temperatures>24.0</temperatures>
 <temperatures>25.0</temperatures> <temperatures>25.0</temperatures>
Line 168: Line 168:
 Example XML: Example XML:
  
-<code><baseBoard rcuPosition="6" baseboardType="APLS" id="RCU_84055620466592_BB_6" infrastructurePower="9.8" rcuId="RCU_84055620466592">+<code xml><baseBoard rcuPosition="6" baseboardType="APLS" id="RCU_84055620466592_BB_6" infrastructurePower="9.8" rcuId="RCU_84055620466592">
 <nodeId>RCU_84055620466592_BB_6_1</nodeId> <nodeId>RCU_84055620466592_BB_6_1</nodeId>
 <nodeId>RCU_84055620466592_BB_6_2</nodeId> <nodeId>RCU_84055620466592_BB_6_2</nodeId>
Line 196: Line 196:
 Example XML: Example XML:
  
-<code><rcu rcuType="ANTARES" fanSpeed="60" rackId="RCK_1" name="RECSMaster (RCU) on 192.168.56.195" rackPosition="0" id="RCU_84055620466592">+<code xml><rcu rcuType="ANTARES" fanSpeed="60" rackId="RCK_1" name="RECSMaster (RCU) on 192.168.56.195" rackPosition="0" id="RCU_84055620466592">
 <backplaneId>RCU_84055620466592_BP_1</backplaneId> <backplaneId>RCU_84055620466592_BP_1</backplaneId>
 <baseBoardId>RCU_84055620466592_BB_1</baseBoardId> <baseBoardId>RCU_84055620466592_BB_1</baseBoardId>
Line 226: Line 226:
 Example XML: Example XML:
  
-<code><rack description="Default rack" id="RCK_1">+<code xml><rack description="Default rack" id="RCK_1">
 <rcuId>RCU_84055620466592</rcuId> <rcuId>RCU_84055620466592</rcuId>
 </rack></code> </rack></code>
Line 283: Line 283:
 The software integration work to monitor the RECS<sup>(r)</sup>%%|%%Box System is quite simple as the the TOR-Master provides monitoring information in the Nagios native NRPE format. So only the NRPE plugin has to be installed and configured as follows. Here, a sample output can be found: The software integration work to monitor the RECS<sup>(r)</sup>%%|%%Box System is quite simple as the the TOR-Master provides monitoring information in the Nagios native NRPE format. So only the NRPE plugin has to be installed and configured as follows. Here, a sample output can be found:
  
-<code>$ /usr/lib/nagios/plugins/check_nrpe -H 10.11.12.244 \ +<code bash>$ /usr/lib/nagios/plugins/check_nrpe -H 10.11.12.244 \ 
-            -c check_temp -a 10.11.12.244 10 2 30 40+            -c check_temp -a 10.11.12.244 10 2 70:104 105:
  
-OK - Temperature: 29 C|temp=29,000000;30;40;10,000000;105,000000+OK - Temperature: 29 C|temp=29,000000;70:104;105;70,000000;105,000000
 </code> </code>
  
Line 294: Line 294:
 | ''-H'' | Host to ask for data, this is always the IP of the TOR-Master (example: 10.11.12.244) | | ''-H'' | Host to ask for data, this is always the IP of the TOR-Master (example: 10.11.12.244) |
 | ''-c'' | Plugin to run. Can be ''check_temp'' or ''check_power'' | | ''-c'' | Plugin to run. Can be ''check_temp'' or ''check_power'' |
-| ''-a''Options to pass to the plugin, see more details in tables below |+| ''-a''Arguments to pass to the plugin, see more details in tables below |
  
-Options for ''check_temp'' plugin: \\+Arguments for ''check_temp'' plugin: \\
  
-Option example ^ Description ^+Argument example ^ Description ^
 | ''10.11.12.244'' | Get sensor values from device with this IP (RCU/RPU) | | ''10.11.12.244'' | Get sensor values from device with this IP (RCU/RPU) |
 | ''10'' | Get sensor values from this baseboard (''1'' - ''18'') | | ''10'' | Get sensor values from this baseboard (''1'' - ''18'') |
 | ''2'' | Get values from this sensor (''max'', ''inlet'', ''outlet'', ''0'', ''1'', ''2'', ''3'', ''4'') | | ''2'' | Get values from this sensor (''max'', ''inlet'', ''outlet'', ''0'', ''1'', ''2'', ''3'', ''4'') |
-| ''30''Upper warning threshold | +| ''70:104''Range of warning threshold | 
-| ''40''Upper critical threshold |+| ''105''Range critical threshold (ending with '':'' means open end) |
  
-Options for the ''check_power'' plugin: \\+Arguments for the ''check_power'' plugin: \\
  
-Option example ^ Description ^+Argument example ^ Description ^
 | ''10.11.12.244'' | Get sensor values from device with this IP (RCU/RPU) | | ''10.11.12.244'' | Get sensor values from device with this IP (RCU/RPU) |
 | ''10'' | Get sensor values from this baseboard (''1'' - ''18'') |     | ''10'' | Get sensor values from this baseboard (''1'' - ''18'') |    
 | ''2'' | Get sensor values from this node (''1'', ''2'', ''3'', ''4'') | | ''2'' | Get sensor values from this node (''1'', ''2'', ''3'', ''4'') |
-| ''30''Upper warning threshold [Watt] | +| ''80:110''Range of warning threshold [Watt] | 
-| ''40''Upper critical threshold [Watt] |+| ''110:''Range of critical threshold [Watt] |