meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
documentation:physical_interface [2016/12/14 15:18] – [Control panel] vordoc_recs3:physical_interface [2020/03/04 13:05] – ↷ Page moved from documentation:physical_interface to doc_recs3:physical_interface kru
Line 23: Line 23:
 ^  Antares  ^  Arneb  ^ Description ^ ^  Antares  ^  Arneb  ^ Description ^
 |  {{:documentation:lcd_recs_box_rcu_192_168_13_50.png?nolink&288|}}  || Shows the IP address of the RCU. | |  {{:documentation:lcd_recs_box_rcu_192_168_13_50.png?nolink&288|}}  || Shows the IP address of the RCU. |
-|  {{:documentation:lcd_health_ok_72_cpus_install.png?nolink&288|Arneb}}  |  {{:documentation:lcd_health_ok_24_cpus_2_psus.png?nolink|Antares}}  | Displays the current health status of the RCU and the number of compute modules installed. On the Antares the number of PSU****s installed is also shown. |+|  {{:documentation:lcd_health_ok_72_cpus_install.png?nolink&288|Arneb}}  |  {{:documentation:lcd_health_ok_24_cpus_2_psus.png?nolink&288|Antares}}  | Displays the current health status of the RCU and the number of compute modules installed. On the Antares the number of PSU****s installed is also shown. |
 |  {{:documentation:lcd_6_on_42_w_avg_temp_28_c.png?nolink&288|}}  || In the first row the number of currently turned on compute modules is shown along with their current power consumption. The second row shows the current average temperature. | |  {{:documentation:lcd_6_on_42_w_avg_temp_28_c.png?nolink&288|}}  || In the first row the number of currently turned on compute modules is shown along with their current power consumption. The second row shows the current average temperature. |
 |  {{:documentation:lcd_0_off_l000200001_0_on_r030000000.png?nolink&288|Arneb}}  |  {{:documentation:lcd_0_off_l000_0_0_on_r000_0.png?nolink&288|Antares}}  | Shows the node on/off status for each baseboard. For ARM baseboards the number of nodes on is shown (0-4). A dash ("-") indicates baseboards that are not populated or where not found. In case of an Antares RCU also the status of the power supplies is shown. "L" and "R" mark the orientation of the display and are shown as looking onto the front panel. | |  {{:documentation:lcd_0_off_l000200001_0_on_r030000000.png?nolink&288|Arneb}}  |  {{:documentation:lcd_0_off_l000_0_0_on_r000_0.png?nolink&288|Antares}}  | Shows the node on/off status for each baseboard. For ARM baseboards the number of nodes on is shown (0-4). A dash ("-") indicates baseboards that are not populated or where not found. In case of an Antares RCU also the status of the power supplies is shown. "L" and "R" mark the orientation of the display and are shown as looking onto the front panel. |
Line 53: Line 53:
  
 ^  Display  ^ Description ^ ^  Display  ^ Description ^
-| {{:documentation:lcd_recs_box_rpu_192_168_13_50.png?nolink|}} | Shows the IP address of the RPU | +| {{:documentation:lcd_recs_box_rpu_192_168_13_50.png?nolink&288|}} | Shows the IP address of the RPU | 
-| {{:documentation:lcd_health_ok_10_psus_install.png?nolink|}} | Displays the current health status of the RPU and the number of power supplies installed. | +| {{:documentation:lcd_health_ok_10_psus_install.png?nolink&288|}} | Displays the current health status of the RPU and the number of power supplies installed. | 
-| {{:documentation:lcd_2_on_15_w_oe_load.png?nolink|}}| Shows the numer of power supplies that are currenty on, and the power provided by the RPU. A percentage bar (10% steps) of the load is shown in the lower line. | +| {{:documentation:lcd_2_on_15_w_oe_load.png?nolink&288|}}| Shows the numer of power supplies that are currenty on, and the power provided by the RPU. A percentage bar (10% steps) of the load is shown in the lower line. | 
-| {{:documentation:lcd_0_off_l_00001_e_1_on_r_00001_e.png?nolink|}}| Shows the on/off status for each power supply (0=off 1= on). A dash (“-”) indicates power supplies that are not populated or where not found. “L” and “R” mark the orientation of the display and are shown as looking onto the front panel. |+| {{:documentation:lcd_0_off_l_00001_e_1_on_r_00001_e.png?nolink&288|}}| Shows the on/off status for each power supply (0=off 1= on). A dash (“-”) indicates power supplies that are not populated or where not found. “L” and “R” mark the orientation of the display and are shown as looking onto the front panel. |
  
 ==== Power connectors ==== ==== Power connectors ====