meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
documentation:physical_interface [2016/12/14 15:22] – [Control panel] vordoc_recs3:physical_interface [2020/03/04 13:09] (current) – ↷ Links adapted because of a move operation kru
Line 53: Line 53:
  
 ^  Display  ^ Description ^ ^  Display  ^ Description ^
-| {{:documentation:lcd_recs_box_rpu_192_168_13_50.png?nolink|}} | Shows the IP address of the RPU | +| {{:documentation:lcd_recs_box_rpu_192_168_13_50.png?nolink&288|}} | Shows the IP address of the RPU | 
-| {{:documentation:lcd_health_ok_10_psus_install.png?nolink|}} | Displays the current health status of the RPU and the number of power supplies installed. | +| {{:documentation:lcd_health_ok_10_psus_install.png?nolink&288|}} | Displays the current health status of the RPU and the number of power supplies installed. | 
-| {{:documentation:lcd_2_on_15_w_oe_load.png?nolink|}}| Shows the numer of power supplies that are currenty on, and the power provided by the RPU. A percentage bar (10% steps) of the load is shown in the lower line. | +| {{:documentation:lcd_2_on_15_w_oe_load.png?nolink&288|}}| Shows the numer of power supplies that are currenty on, and the power provided by the RPU. A percentage bar (10% steps) of the load is shown in the lower line. | 
-| {{:documentation:lcd_0_off_l_00001_e_1_on_r_00001_e.png?nolink|}}| Shows the on/off status for each power supply (0=off 1= on). A dash (“-”) indicates power supplies that are not populated or where not found. “L” and “R” mark the orientation of the display and are shown as looking onto the front panel. |+| {{:documentation:lcd_0_off_l_00001_e_1_on_r_00001_e.png?nolink&288|}}| Shows the on/off status for each power supply (0=off 1= on). A dash (“-”) indicates power supplies that are not populated or where not found. “L” and “R” mark the orientation of the display and are shown as looking onto the front panel. |
  
 ==== Power connectors ==== ==== Power connectors ====
Line 65: Line 65:
 ===== Sensors ===== ===== Sensors =====
  
-Each Baseboard of the RECS<sup>(r)</sup>%%|%%Box system includes five temperature sensors that are regularly polled by the management software. This data is available in raw format via all [[Software interface|software interfaces]] provided by the TOR Master. Additionally, the TOR Master calculates some derived temperatures: Inlet- and outlet temperature (Arneb only) as well as the highest temperatures on baseboard, RCU and cluster level.+Each Baseboard of the RECS<sup>(r)</sup>%%|%%Box system includes five temperature sensors that are regularly polled by the management software. This data is available in raw format via all [[documentation:software_interface|software interfaces]] provided by the TOR Master. Additionally, the TOR Master calculates some derived temperatures: Inlet- and outlet temperature (Arneb only) as well as the highest temperatures on baseboard, RCU and cluster level.
  
 ==== Locations ==== ==== Locations ====